- The exact measured energy efficient ratio (EER) of the products shall meet the requirements defined by the latest version of the National Standards Bureau or the National Energy Commission.
- The product value of dB depends on the CNS 3615 newest versions and method should follow the standard:
Capacity of the Household-use air conditioner (kW) |
Indoor (dB) |
Outdoor (dB) |
Under 2.3kW |
less or equal 50 |
less or equal 53 |
Between 2.3kW to 4.1kW |
less or equal 53 |
less or equal 57 |
Over 4.1kW |
less or equal 58 |
less or equal 62 |
- Plastic components of the product weighting 25 g or greater shall meet the following requirements:
- shall not contain cadmium, lead, chromium (+6) or mercury;
- shall not contain the following flame retardants:
- polybrominated biphenyls, (PBB);
- polybrominated diphenylethers, (PBDE): monobrominated diphenylether, dibrominated diphenylether, tribrominated diphenylether, tetrabrominated diphenylether, pentabrominated diphenylether, hexabrominated diphenylether, heptabrominated diphenylether, octabrominated diphenylether, nanobrominated diphenylether, decabrominated diphenylether.
- long-chained chloroparaffins with 10-13 carbon atoms per The product and its manufacturing process shall not contain or use substances controlled by the Montreal Protocol.
- The painting material must not include the mercury, mercury compounds or mixed with dyes stuff containing lead, cadmium, chromium (+6) and their oxides. The products shall not have any organic solvent residue.
- The name and address of the Green Mark user must be clearly printed on the product or on the packaging material. For non-manufacturing Logo users, the manufacturer's name and address shall also be shown.
- The product or the packaging material shall bear a label reading "saving energy, low noise".
Remark:
- Corrugated carton used for packaging is recommended to be made from recycled pulp with at least 80% recycled paper. The packaging material shall not use CFC foaming agent as filler.
- The energy efficient ratio (EER) shall be indicated in the catalogue.
- The noise level shall be indicated in the user's manual.
- The determination of polybrominated biphenyls and polybrominated diphenylethers flame retardants should be based on international, national or specific industry standards, such as the US EPA 3540C/8081A/8082A/8270D, and the detection limits should be no greater than 5 ppm.
- The determination of long-chained chloroparaffins with 10-13 carbon atoms per molecule should be based, in the order of preference, on international, national or specific industry standards, such as the US EPA 8270D/3540C/GC-MSD, and the detection limits should be no greater than 5 ppm.
- The determination of cadmium, lead, chromium (+6) and mercury, should be based, in the order of preference, on international, national or specific industry standards, such asUS EPA 3050B/3051A/3052/3060A, and the detection limits should be no greater than 2 ppm.
|
|
|